Benchtop Spectrophotometer

Description: For applications requiring extremely high precision in color control, benchtop spectrophotometers offer significant advantages. Compared to portable spectrophotometers, benchtop models feature a more stable optical structure, enabling the detection of very subtle color differences (e.g., ΔE < 0.015). Additionally, inter-instrument variation (ΔE*ab) can be controlled within 0.15, making them ideal for demanding scenarios such as scientific research and quality inspection.


Key Features:

◆ Adopts the internationally recognized D/8 structure, compatible with SCI/SCE measurement, and supports simultaneous fast measurement of SCI+SCE.

◆ Equipped with a 7 inch standalone rotatable tablet (Android), offering fast response and convenient operation.

◆ Dual-array CMOS image sensor with high sensitivity and a broad spectral response range, enabling high-precision and highly repeatable measurements.

◆ Provides 40+ measurement indices and 41 light sources, including D65, A, C, D50, D55, D75, F1-F12, CWF, DLF, TL83, TL84, TPL5, U30B, U35, NBF, ID50, ID65, LED-B1-B5, LED-BH1, LED-RGB1, LED-V1/V2, LED-C2/C3/C5, and customizable sources (some via PC software), meeting specialized measurement needs under various conditions.

◆ Utilizes composite full-spectrum LED light sources (360nm~780nm), including UV, 400nm cut-off, 420nm cut-off, and 460nm cut-off options.

◆ Automatic aperture recognition: Supports Φ25.4mm, Φ15mm, Φ8mm, and Φ4mm measurement apertures, allowing flexible configuration of aperture and lens position to accommodate special measurement requirements.

◆ Multi-directional measurement capability: Side, upward, and downward (with accessories) measurement options; open transmission compartment (supports samples up to 54mm thick) for broader sample compatibility.

◆ Built-in camera for framing and positioning: Real-time camera view ensures precise alignment of the measurement target, improving efficiency and accuracy.

◆ Includes SQCX quality management software, suitable for quality control and color data management across industries. Digitizes color management, compares color differences, generates test reports, provides multiple color space data, and customizes color workflows.

◆ Automatic temperature and humidity compensation ensures more accurate measurement results.


BGD 554-02E.jpg

Technical Items →

Ordering Information ↓

BGD 554/1
Basic Benchtop Spectrophotometer

BGD 554/2
Premium Benchtop Spectrophotometer

Illumination Method

Reflection: D/8 (diffuse illumination, 8° receiving angle)

Transmission: D/0 (diffuse illumination, 0° receiving angle)

Supports SCI/SCE measurement, UV inclusion/exclusion measurement, and haze (ASTM D1003)

Complies with CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO 7724/1, ASTM E1164, DIN 5033 Teil 7, JIS Z8722 Condition C

Integrating Sphere Size

Φ154mm

Light Source

360nm~780nm composite LED light source, including UV, 400nm cut-off, 420nm cut-off, and 460nm cut-off options

Spectroscopic Method

Concave grating

Sensor

256-pixel dual-array CMOS image sensor

Measurement

Wavelength Range

360nm~780nm

Wavelength Interval

10nm

Bandwidth (FWHM)

5nm

Reflectance Measurement Range

0~200%

Reflectance Resolution

0.01

Measurement Apertures

Reflection: XLAV Φ25.4mm/Φ30mm、LAV Φ15mm/Φ18mm 、MAV Φ8mm/Φ10mm 、SAV Φ4mm/Φ6mm;  
Transmission: Φ25.4mm (no height/thickness restriction, max. thickness ≤54mm);

Note:

1-Automatic aperture switching & recognition

2-Users can configure aperture and lens position as needed

Measurement Modes

Reflection (SCI/SCE), Transmission (SCI/SCE)

Color Spaces

CIE LAB、XYZ、Yxy、LCh、CIE LUV、

Musell、s-RGB、HunterLab、βxy、DIN Lab99

Color Difference Formulas

ΔE*ab、ΔE*uv、ΔE*94、ΔE*cmc(2:1)、ΔE*cmc(1:1)、

ΔE*00、 DINΔE99、ΔE(Hunter) ,ΔE*CH,555 Hue Classification

Other Chromatic Indices

Whiteness (WI): ASTM E313, CIE/ISO, AATCC, Hunter, Taube, Berger Stensby;

Yellowness (YI):ASTM D1925,ASTM 313;

ISO Brightness, R457, Metamerism Index (Mt), Color Fastness, Staining Fastness, Strength, Opacity,APHA/Hazen/Pt-Co (Platinum-Cobalt Index), Gardner Index, Haze Transmittance (ASTM D1003), Saybolt Index,ASTM D1500 Color Scale, 8° Gloss, 555 Hue Classification, Blackness (My, dM),Color Density (CMYK - A/T/E/M), Tint, Spectral Density (some functions require PC software)

Observer Angle

2°/10°

Light Sources

D65、A、C、D50、D55、D75、F1、F2、F3、F4,F5,F6、F7、F8、F9,F10、F11、F12、CWF、DLF、TL83、TL84、TPL5、U30,B、U35、NBF、ID50、ID65、LED-B1、LED-B2、LED-B3、LED-B4、LED-B5、LED-BH1、LED-RGB1、LED-V1、LED-V2、LED-C2、LED-C3、LED-C5 and customizable sources (41 total, some via PC software)

Display

Spectrum graph/data, sample chromaticity values, color difference/graph, chromaticity diagram, color simulation, pass/fail results, color deviation,

color evaluation, haze, liquid chromaticity

Measurement Time

Approx. 2.0s (approx. 4s for simultaneous SCI/SCE measurement)

Repeatability

Reflection Chromaticity (Φ25.4mm/SCI): ΔE*ab ≤ 0.015 (avg. standard deviation of 30 white tile measurements at 5s intervals after warm-up & calibration)

Spectral Reflectance/Transmittance: ≤ 0.1%

Reflection Chromaticity (Φ25.4mm/SCI): ΔE*ab ≤ 0.014 (avg. standard deviation of 30 white tile measurements at 5s intervals after warm-up & calibration)

Spectral Reflectance/Transmittance: ≤ 0.1%

Inter-Instrument Agreement

Φ25.4mm/SCI: ΔE*ab ≤ 0.15

 (avg. of BCRA Series II 12-color tile measurements)

Φ25.4mm/SCI: ΔE*ab ≤ 0.14

 (avg. of BCRA Series II 12-color tile measurements)

Size

440mm×248mm×283mm(L×W×H)

Weight

Approx. 13.5 kg

Power Supply

24V DC, 3A adapter

Light Source Lifetime

5 years (over 3 million measurements )

Display

7 inch standalone rotatable tablet, 32GB storage

Interface

USB, Bluetooth® 5.0, printer serial port

Data Storage

32GB, supports >100,000 records (SCI/SCE counted as one record)

Languages

Simplified Chinese, Traditional Chinese, English (customizable: German, French, Spanish, Russian, Japanese, Thai, Korean, Polish, Portuguese)

Standard Accessories

Power adapter, user manual, quality management software (USB drive), data cable, calibration tiles, black calibration box, transmission black baffle, sample holder, 25.4/15/8/4mm apertures, transmission fixture set, cuvette, 10.5" tablet

Optional Accessories

Mini printer, inverted stand, Petri dish, micro-well (4mm) transmission fixture set, film holder


Subject:
Company:*
Name:
E-mail:*
Country:*
Comments:
Verification Code:Click ChangeCan't see clearly. Change it?
 
Send message
Contact USMore

Biuged Precise Instruments (Guangzhou) Co.,Ltd

Add:NO.15, Fuzhong Rd., Zhongxin Town, 

Zengcheng District, Guangzhou.China

Tel:+86-20-32955999;+86-20-32955820

Fax:+86-20-32955819 

E-mail:jack@biuged.com

Website: http://www.biuged.com 


Biuged Instruments Co.,Ltd.

Add:RM.310, NO.1, Sicheng Rd.,
Tianhe District, Guangzhou.China

Tel:+86-20-82169666

Fax:+86-20-32955818

E-mail:jack@biuged.com





Biuged Precise Instruments (Shanghai) Co.,Ltd

Add:Room 906, 9th Floor, Zhongcai Industrial Park, No.1111 

Zhu Feng Road, Qingpu District, Shanghai, China

Tel:+86-21-59240298

Fax:+86-21-59249719

E-mail:xjx@biuged.com

  Biuged Laboratory Instruments (Guangzhou) Co., Ltd.   Guangdong ICP record number:11044672